System Selector 

The System Selector below will help you choose the correct system. Simply tick the boxes that apply to your situation and click "Search Systems".
You can also use this page to create your own Firestopping Specification. To see how go to Specification Instructions
If you want to restrict your search to a particular product, click your choice from the "Product" dropdown menu. 
If you know the identification number (FCxxx) of the system(s) you want then simply type them into the "System ID" box (separate by commas for multiple numbers) and click "Search Systems".
For an Excel spreadsheet version of all systems, click here for a list of systems.
Important Note: Systems tested in plasterboard may also be used in concrete (AS 1530.4 Section 10.12.2). Therefore all the systems shown below with diagrams in plasterboard may be used in concrete.

Wall
Floor
Ceiling
Plasterboard
Concrete
CLT
Korok/Speedpanel
Plastic Pipe
PEX Pipe
AluPEX Pipe
Metal Pipe
Copper/Brass Pipe
Cables
Cable Trays
Conduits
Pair Coils
Elect Dist Box
Joints and Gaps
Tilt Slab
Steel
Combos
Ducts
Smoke Seal
Blanks
Hatches
Collars

Product :
Required Fire Rating :
System ID(s) :
Search Systems    

Protecta FR Damper Concrete Floor with Mortar

System ID FC474

Damper (round or rectangular) through a concrete floor min 100mm thick, in larger apertures up to 2400x1200mm sealed with Protecta EX Mortar.

Protecta FR Damper Concrete Floor Core-drilled with Putty

System ID FC514

Damper through a concrete floor min 100mm thick, core-drilled with gap less than 10mm. Seal with Protecta FR Putty Cord both sides with mineral wool on top side only.

Protecta FR Damper Concrete Floor Core-drilled with Acrylic

System ID FC515

Damper through a concrete floor min 100mm thick, core-drilled with gap 10mm-30mm. Seal with Protecta FR Acrylic sealant backed by mineral wool both sides. Wrap with mineral wool on top side only.

Protecta FR Damper Plasterboard Ceiling Ventilation Duct

System ID FC417

Ventilation duct through a plasterboard ceiling or floor/ceiling system. Protecta FR Damper in vertical orientation. FRR relates to internal fire only. Max FRR -/180/-

Protecta FR Damper Concrete Wall

System ID FC475

Damper (round or rectangular) through a concrete wall min 100mm thick, core-drilled sealed with FR Acrylic or in aperture up to 1200mm high with unlimited width sealed with Protecta FR Board.

Protecta FR Damper Plasterboard Wall

System ID FC477

Damper (round or rectangular) through a plasterboard wall min 100mm thick, core-drilled sealed with FR Acrylic or in aperture up to 1200mm high with unlimited width sealed with Protecta FR Board.