System Selector 

Use the Firestop Centre System Selector below to identify the most appropriate firestopping system for your project. Select the criteria that correspond to your firestopping requirements to view relevant options.

Additional features include:

  • The ability to create a custom Firestopping Specification — refer to the Specification Instructions Specification Instructions for guidance.
  • Filtering results by selecting a product from the Product dropdown menu.
  • Searching by system FC number by entering one or more FC numbers in the System ID box, separated by commas.
Substrate:   
Wall
Floor
Ceiling
Plasterboard
Concrete
CLT
Korok/Speedpanel
Hebel
Shaftwall

Penetrant:   
Metal Pipe
Copper/Brass Pipe
Cables
Cable Trays
Conduits
Pair Coils
Elect Dist Box
Joints and Gaps
Steel
Ducts
Blanks
Hatches
Naked Wall
Plastic Pipe
PEX Pipe
AluPEX Pipe

Product :
Required Fire Rating :
System ID(s) :
Search Systems    

AGNI-Black PEX Pipe - 2 x 13mm PB Wall

System ID FC865

Service Penetration: PEX pipe, 16-40mm
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Black PEX Pipe – 1 x 13mm PB Wall

System ID FC887

Service Penetration: PEX pipe, 16-32mm
Substrate: 1 x 13mm Plasterboard wall or concrete wall, min 116mm thick
Max FRR: -/60/60

AGNI-Black PEX-AL-PEX Pipe - 2 x 13mm PB Wall

System ID FC864

Service Penetration: PEX-AL-PEX pipe, 16-32mm
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min, 116mm thick
Max FRR: -/120/120

AGNI-Black PEX-AL-PEX Pipe - 1 x 13mm PB Wall

System ID FC855

Service Penetration: PEX-AL-PEX pipe, 16-32mm
Substrate: 1 x 13mm Plasterboard wall or concrete wall, min 90mm thick
Max FRR: -/60/60

AGNI-Black PB Pipe - 2 x 13mm PB Wall

System ID FC435

Service Penetration: Polybutylene (PB) pipe, 15-28mm
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min 116mm thick
Max FRR: -/120/120

AGNI-Black Mixed Pair Coil Services - 2 x 13mm PB Wall

System ID FC885

Service Penetration: Mixed pair coil services - FR pair coil with or without TPS cable and PVC pipe
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min.116mm thick
Max FRR: -/120/120

AGNI-Black Mixed Pair Coil Services - 1 x 13mm PB Wall

System ID FC889

Service Penetration: Mixed pair coil services - FR pair coil with or without TPS cable and PVC pipe
Substrate: 1 x 13mm Plasterboard wall or concrete wall, min. 90mm thick or greater
Max FRR: -/60/60

AGNI-Black PE Pair Coil - 2 x 13mm PB Wall

System ID FC886

Service Penetration: PE pair coil
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/60

AGNI-Black PE Pair Coil - 1 x 13mm PB Wall

System ID FC888

Service Penetration: PE Pair Coil
Substrate: 1 x 13mm Plasterboard wall or concrete wall, min. 90mm thick 
Max FRR: -/60/45

AGNI-Sleeve Insulated Copper Pipe - 2 x 13mm PB Wall

System ID FC361

Service Penetration: Copper Pipe 15-50mm with nitrile rubber insulation 9-38mm thick
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve 2 x Insulated Copper Pipes - 2 x 13mm PB Wall

System ID FC288

Service Penetration: 2 x Copper pipes (32mm & 15mm) with 32mm & 25mm nitrile rubber insulation
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve 3 x Insulated Copper Pipes- 2 x 13mm PB Wall

System ID FC362

Service Penetration: 3 x Copper Pipes (15mm, 32mm & 50mm) with 32mm & 25mm nitrile rubber insulation
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve Insulated PEX Pipe - 2 x 13mm PB Wall

System ID FC551

Service Penetration: PEX Pipe 16-32mm with nitrile rubber insulation 9-38mm thick
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Wrap PVC Conduit with Fibre Optic Cables - 2 x 13mm PB Wall

System ID FC448

Service Penetration: 25mm PVC Conduit empty or filled with up to 8 fibre optic cables
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm
Max FRR: -/120/120

AGNI-Wrap Flexible Conduit with Fibre Optic Cables - 2 x 13mm PB Wall

System ID FC451

Service Penetration: 25mm Flexible Conduit empty or filled with up to 8 fibre optic cables
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick 
Max FRR: -/120/120

AGNI-Wrap PEX Pipe - Hebel Wall

System ID FC831

Service Penetration: 25mm PEX pipe
Substrate: Hebel wall, min. 75mm thick
Max FRR: -/120/120

AGNI-Wrap PEX Pipe - Shaftwall

System ID FC452

Service Penetration: PEX pipe 16-20mm
Substrate: Shaftwall - 25mm Shaftliner and 16mm FR plasterboard
Max FRR: -/60/60

AGNI-Wrap Shaftwall PEX Pipe 25mm

System ID FC218

PEX pipe (25mm) through a Shaftwall (25mm Shaftliner and 16mm FR plasterboard). AGNI-Wrap 50 single layer each side of wall with AGNI-Black sealant. Max FRR -/60/60.

AGNI-Wrap Shaftwall Conduit, Empty or Filled

System ID FC453

Conduit (PVC, 25mm, empty or filled with data, alarm, fibre optic cables) through a Shaftwall (25mm Shaftliner and 16mm FR plasterboard). AGNI-Wrap 50 single layer each side of wall with AGNI-Black sealant. Max FRR -/60/60

AGNI-Wrap Hebel Wall Pair Coil (PE or FR)

System ID FC833

Pair Coil with cable and pipe through a Hebel wall (75mm or greater). AGNI-Wrap single layer each side of wall with AGNI-Black sealant. Max FRR -/120/120.

AGNI-Wrap Shaftwall Pair Coil (PE or FR)

System ID FC219

Pair Coil with cable and pipe through a Shaftwall (25mm Shaftliner and 16mm FR plasterboard). AGNI-Wrap single layer each side of wall with AGNI-Black sealant. Max FRR -/60/60.

AGNI-Wrap Pbd (1x13mm) or Concrete Wall PE Pair Coils Single or Double inc cables

System ID FC892

Pair Coils, single or double, PE insulation with TPS cable through a 1 x 13mm plasterboard wall or concrete wall (90mm or greater). AGNI-Wrap in aperture with AGNI-Black sealant between wrap and coils. Finish with AGNI-Seal fillet over exposed AGNI-Wrap. Max FRR -/60/60.