System Selector 

Use the Firestop Centre System Selector below to identify the most appropriate firestopping system for your project. Select the criteria that correspond to your firestopping requirements to view relevant options.

Additional features include:

  • The ability to create a custom Firestopping Specification — refer to the Specification Instructions Specification Instructions for guidance.
  • Filtering results by selecting a product from the Product dropdown menu.
  • Searching by system FC number by entering one or more FC numbers in the System ID box, separated by commas.
Substrate:   
Wall
Floor
Ceiling
Plasterboard
Concrete
CLT
Korok/Speedpanel
Hebel
Shaftwall

Penetrant:   
Metal Pipe
Copper/Brass Pipe
Cables
Cable Trays
Conduits
Pair Coils
Elect Dist Box
Joints and Gaps
Steel
Ducts
Blanks
Hatches
Naked Wall
Plastic Pipe
PEX Pipe
AluPEX Pipe

Product :
Required Fire Rating :
System ID(s) :
Search Systems    

AGNI-Sleeve Concrete Floor/Ceiling PVC Pipe Top Fix

System ID FC806

Plastic pipe (PVC-U, 32-150mm) through a concrete or AAC floor or ceiling (100mm or greater). Single AGNI-Sleeve top fixed with tabs and 10mm AGNI-Seal sealant at top of floor/ceiling. Max FRR -/120/120.

AGNI-Sleeve Concrete Floor/Ceiling PVC Pipe Top Fix 360min

System ID FC857

Plastic pipe (PVC-U, up to 100mm) through a concrete or AAC floor or ceiling (190mm or greater). Single AGNI-Sleeve with tabs top fixed with 10mm AGNI-Seal sealant at top of floor/ceiling. Max FRR -/360/360.

AGNI-Sleeve Composite Floor PVC Pipe Top Fix

System ID FC867

Plastic pipe (PVC-U, up to 100mm diam) through a composite floor (topping min 70mm). Single AGNI-Sleeve top fixed with 10mm AGNI-Seal at top of floor. Max FRR -/60/60.

AGNI-Sleeve Composite Floor PVC Pipe Bottom Fix

System ID FC880

Plastic pipe (PVC-U, 32-100mm diam) through a composite floor (topping min 70mm). Single AGNI-Sleeve bottom fixed with 20mm AGNI-Board at top of floor. Max FRR -/60/60.

AGNI-Sleeve Concrete Floor/Ceiling PPR Pipe Top Fix

System ID FC813

Aquatherm plastic pipe (PPR, 32-90mm) through a concrete or AAC floor/ceiling (100mm or greater). Single AGNI-Sleeve top fixed with tabs with 10mm AGNI-Seal sealant to top of floor/ceiling. Max FRR -/120/120.

AGNI-Sleeve Concrete Floor/Ceiling PPR Pipe Top Fix 360min

System ID FC858

Aquatherm plastic pipe (PPR, 125mm) through a concrete or AAC floor/ceiling (190mm or greater). Double layer AGNI-Sleeve with tabs top fixed with 10mm AGNI-Seal sealant to top of floor/ceiling. Max FRR -/360/360.

AGNI-Sleeve Composite Floor PP-R Pipe Top Fix

System ID FC868

Aquatherm plastic pipe (PP-R, 90mm) through a composite floor (topping min 70mm). Single AGNI-Sleeve top fixed with 10mm AGNI-Seal sealant to top of floor. Max FRR -/120/120.

AGNI-Sleeve Composite Floor PP-R Pipe Bottom Fix

System ID FC881

Aquatherm plastic pipe (PP-R, 90mm) through a composite floor (topping min 70mm). Single AGNI-Sleeve bottom fixed with 20mm AGNI-Board to top of floor. Max FRR -/60/60.

AGNI-Sleeve Composite Floor Flexible Conduit Top Fix

System ID FC870

Flexible Conduit 50mm, empty or with up to 6 x TPS cables through a composite floor (topping min 70mm). Single AGNI-Sleeve with tabs top fixed with 10mm AGNI-Seal sealant to top of floor. Max FRR -/120/120.

AGNI-Sleeve Composite Floor Flexible Conduit Bottom Fix

System ID FC879

Flexible Conduit 50mm, empty or with TPS cables through a composite floor (topping min 70mm). Single AGNI-Sleeve with tabs bottom fixed with 20mm AGNI-Board to top of floor. Max FRR -/60/60.

AGNI-Sleeve Composite Floor Pair Coil Top Fix

System ID FC869

Pair Coil with condensate pipe and TPS cable through a composite floor (topping min 70mm). Single AGNI-Sleeve with tabs top fixed with 10mm AGNI-Seal sealant to top of floor. Max FRR -/120/90.

AGNI-Sleeve Concrete Floor/Ceiling PVC Pipe Bottom Fix

System ID FC814

Plastic pipe (PVC-U, 32-100mm) through a concrete or AAC floor/ceiling (120mm or greater). Single AGNI-Sleeve bottom fixed with 20mm AGNI-Seal sealant to bottom of floor/ceiling. Max FRR -/120/120.

AGNI-Sleeve Concrete Floor/Ceiling PPR Pipe Bottom Fix

System ID FC815

Aquatherm plastic pipe (PPR, 40-90mm) through a concrete or AAC floor/ceiling (120mm or greater). Single AGNI-Sleeve bottom fixed with 20mm AGNI-Seal sealant to bottom of floor/ceiling. Max FRR -/120/120.

AGNI-Sleeve Concrete Floor/Ceiling Floor Waste 360min

System ID FC859

Floor waste (80mm with PVC elbow) through a concrete or AAC floor/ceiling (190mm or greater). Single layer AGNI-Sleeve with tabs and ceramic backing. Max FRR -/360/360.

AGNI-Sleeve Pbd or Concrete Wall PVC Pipe

System ID FC816

Plastic pipe (PVC-U, 80-100mm) through a 1 x 13mm plasterboard wall or concrete wall (116mm or greater). Single AGNI-Sleeve extending 25mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/60.

AGNI-Sleeve Pbd or Concrete Wall PEX Pipe

System ID FC827

PEX pipe (40mm) through a 1 x 13mm plasterboard wall or concrete wall (116mm or greater). Single AGNI-Sleeve extending 25mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/60.

AGNI-Sleeve Pbd or Concrete Wall Kelox Pipe

System ID FC854

Kelox Pipe (PERT-AL-PERT) with PE Foam insulation up to 13mm thick through a 1 x 13mm plasterboard wall or concrete wall (118mm or greater). Single AGNI-Sleeve extending 10mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/45.

AGNI-Sleeve Insulated Copper Pipe - 2 x 13mm PB Wall

System ID FC361

Service Penetration: Copper Pipe 15-50mm with nitrile rubber insulation 9-38mm thick
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve 2 x Insulated Copper Pipes - 2 x 13mm PB Wall

System ID FC288

Service Penetration: 2 x Copper pipes (32mm & 15mm) with 32mm & 25mm nitrile rubber insulation
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve 3 x Insulated Copper Pipes- 2 x 13mm PB Wall

System ID FC362

Service Penetration: 3 x Copper Pipes (15mm, 32mm & 50mm) with 32mm & 25mm nitrile rubber insulation
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve Pbd (2x13mm) or Concrete Wall Pair Coils Single or Double FR or PE with Cables

System ID FC609

Pair Coils (single or double set of pair coils with TPS cables, PE or FR insulation) through a 2 x 13mm plasterboard wall or concrete wall (116mm or greater). Single AGNI-Sleeve extending 25mm from each side of wall with AGNI-Straps and AGNI-Seal. Max FRR -/120/60.

AGNI-Sleeve Insulated PEX Pipe - 2 x 13mm PB Wall

System ID FC551

Service Penetration: PEX Pipe 16-32mm with nitrile rubber insulation 9-38mm thick
Substrate: 2 x 13mm Plasterboard wall or concrete wall, min. 116mm thick
Max FRR: -/120/120

AGNI-Sleeve CLT Wall PVC Pipe

System ID FC844

PVC-U pipe (32mm - 80mm) through a 100mm CLT wall. Single AGNI-Sleeve extending 10mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/60.

AGNI-Sleeve CLT Wall PEX Pipe

System ID FC843

PEX pipe (16mm - 25mm) through a 100mm CLT wall. Single AGNI-Sleeve extending 10mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/60.

AGNI-Sleeve CLT Wall 25mm Flexible Conduit with Cables

System ID FC845

Flexible Conduit (25mm) through a 100mm CLT wall. Single AGNI-Sleeve extending 10mm from each side of wall with AGNI-Seal sealant. Max FRR -/60/60.

AGNI-Sleeve AGNI-Shield Plasterboard Ceiling TPS Cables

System ID FC496

TPS Cable bundle through a 1x13mm + 1x16mm plasterboard ceiling. AGNI-Sleeve/AGNI-Shield wrap with AGNI-Seal. Incipient Fire Rating 60min. Max FRR -/60/60

AGNI-Sleeve AGNI-Shield Plasterboard Ceiling Alarm Cables

System ID FC497

Alarm Cable bundle through a 1x13mm + 1x16mm plasterboard ceiling. AGNI-Sleeve/AGNI-Shield wrap with AGNI-Seal. Incipient Fire Rating 60min. Max FRR -/60/60

AGNI-Sleeve AGNI-Shield Plasterboard Ceiling Data Cables

System ID FC505

Data Cable bundle through a 1x13mm + 1x16mm plasterboard ceiling. AGNI-Sleeve/AGNI-Shield wrap with AGNI-Seal. Incipient Fire Rating 60min. Max FRR -/60/60

AGNI-Sleeve AGNI-Shield Plasterboard Ceiling PVC Conduit

System ID FC511

Conduit (25mm PVC) empty or filled with up to 8 fibre optic cables, through a 1x13mm + 1x16mm plasterboard ceiling. AGNI-Sleeve/AGNI-Shield wrap with AGNI-Seal. Incipient Fire Rating 60min. Max FRR -/60/60

AGNI-Sleeve AGNI-Shield Plasterboard Ceiling Copper Pipe

System ID FC555

Copper or steel pipe 25mm-100mm through a 1x13mm + 1x16mm plasterboard ceiling. AGNI-Sleeve/AGNI-Shield wrap with AGNI-Seal. Incipient Fire Rating 60min. Max FRR -/60/45